| Name | Length, mm | Width, mm | Height, mm | LED lifetime, h | Output, lm | Power, W | Efficacy, lm/W | CRI (Ra) | CCT, K | Weight, kg |
| Hercules LED1x3800 G990 T840 L75 | 1224 | 105 | 75 | 100000/L80B10 | 3797 | 21.8 | 174 | 80+ | 4000 | 4.8 |
| Hercules LED1x5300 G991 T840 L75 | 1224 | 105 | 75 | 100000/L80B10 | 5260 | 31.7 | 166 | 80+ | 4000 | 4.8 |
| Hercules LED1x7600 G992 T840 L75 | 1224 | 105 | 75 | 100000/L80B10 | 7554 | 41.6 | 182 | 80+ | 4000 | 4.8 |
| Hercules LED1x4750 G993 T840 L75 | 1524 | 105 | 75 | 100000/L80B10 | 4745 | 26.7 | 178 | 80+ | 4000 | 5.5 |
| Hercules LED1x6600 G994 T840 L75 | 1524 | 105 | 75 | 100000/L80B10 | 6575 | 39.1 | 168 | 80+ | 4000 | 5.5 |
| Hercules LED1x9450 G995 T840 L75 | 1524 | 105 | 75 | 100000/L80B10 | 9443 | 52.0 | 182 | 80+ | 4000 | 5.5 |
Available options:
T830 – Colour temperature 3000K, CRI 80+
T840 – Colour temperature 4000K, CRI 80+
L30 – Optics with 30° beam angle, narrow
L40x75 – Optics with 40×75° beam angle, high rack
L75W – Optics with 60° beam angle, medium
L75 – Optics with 75° beam angle, standard
L90W – Optics with 90° beam angle, wide
L2A25 – Optics with double asymmetric beam, retail
L1A18 – Optics with asymmetric beam
DALI – Driver with DALI interface and switch-control dimming
*note – for DALI LIN option wires are 2×0.5 mm²
BLT – Integrated wireless control unit and driver for lighting control via mobile device (via Bluetooth), with integrated DALI PS
KRBLT – Integrated wireless control unit and driver for lighting control via mobile device (KR system app), on/off
KRBLT DALI – Integrated wireless control unit and driver for lighting control via mobile device (KR system app), DALI with integrated PS
COR – Driver with Corridor function (never off)
COR1min – Driver with Corridor function 1 min (switch off after 1 min)
COR30min – Driver with Corridor function 30 min (switch off after 30 min)
EM3 – Emergency version 3 hours
EM3A – Emergency version equipped with an autonomous testing system, 3 hours
EM3D – Emergency version 3 hours with DALI interface
*note – Operating temperature range for Luminaires with EM option, °C: 0…+35
EM3Atmin-25 – Emergency version equipped with an autonomous testing system, 3 hours. Suitable for low ambient temperatures up to -25 °C
5TB – 5-pole terminal block in middle of luminaire for easy through wiring
1LIN – Through wiring 3×1.5 mm² with two push-in terminal blocks
3LIN – Through wiring 5×1.5 mm² with two push-in terminal blocks
1LIN2.5 – Through wiring 3×2.5 mm² with two push-in terminal blocks
3LIN2.5 – Through wiring 5×2.5 mm² with two push-in terminal blocks